Skip to main content

Installation and Safety

Unpacking​

Your ASP8000 Series Console has been carefully and meticulously tested and inspected before despatch.

Please check for any signs of transit damage. If any signs of mishandling are found, notify the carrier and your dealer immediately.

Check the model number on the power supply fitted to your console before following model-specific PSU instructions. The console package should also contain the power cord, PSU cable and stand hardware.

Important safety instructions​

Read and retain these instructions before connecting the console power supply to the AC mains and the ASP8024. To prevent electrical shock and fire hazard, follow all warnings and instructions marked on the power supply itself.

Mains earth​

This unit is connected via its power cord to the mains safety earth. NEVER OPERATE THE UNIT WITH THIS EARTH CONNECTION REMOVED.

  • Check that the correct operating voltage has been set for your AC mains supply.
  • Check that the fuse fitted is the correct type for the mains voltage selected.
  • Always replace the fuse with the correct type and rating specified for the power supply fitted to the console.

The stand​

The stand will be found beneath the console in the crate. There are two identical legs, a crossmember and two cover panels.

Lay the legs out approximately the width of the console apart and place the crossmember between them. Use the supplied hex-headed M8 bolts to secure the crossmember to each leg; a 13 mm AF spanner will be required. The unused holes in the outside of each leg should be filled using the 9.5 mm caps supplied.

Screw a foot onto the bottom of each leg. Place the stand in an upright position and place the console on top. Secure the console with 12 M6 bolts. Finish by adjusting the feet to take up any unevenness in the floor. There is about 1 inch of adjustment available on each foot. Cover panels for the rear of the stand legs are secured using four M4 screws each.

Service and internal access​

Internal console servicing can require removal of modules, meter pods and internal cabling. Use the current Audient meter-pod and service guidance and only carry out internal work if you are competent to do so. If you are unsure, contact Audient Support before opening the console or disconnecting internal cabling.

Mechanical installation​

Care should be taken not to obstruct the power supply unit's ventilation holes and adequate air flow must be provided within rack cases to prevent the unit from overheating.

Keep all power-supply ventilation slots and fans unobstructed. Position the power supply on a stable surface or in a suitable rack so that adequate airflow is maintained.

The front panel of the ASP8024 Console features a rugged under-surface printed polycarbonate overlay. Exposure to direct sunlight for extended periods should be avoided as this can have a detrimental effect on the overlay panel and on the control knobs.

Mains power supply​

Voltages​

The ASP8120 Console Power Supply features an external mains voltage selector. Switched to the 230 V position, the unit will operate without performance degradation from 210 V to 250 V. In the 115 V setting it will accept from 105 V to 125 V. Do not attempt to operate the unit outside the ranges defined above.

For 100 V operation please contact your dealer.

Fuses​

The fuse ratings for the two voltage ranges are different: 1 1/4 inch T8A for the 230 V setting and 1 1/4 inch T16A for the 115 V setting. Always replace fuses with the same type.

The mains fuse is very unlikely to fail under normal use and caution should be exercised if a failure should occur. Check the mains voltage setting, condition of the mains cord and integrity of the mains supply before replacing the fuse.